Hongfeida Automation
SCHNEIDER	140CPU31110

SCHNEIDER 140CPU31110

0.00
0.00
  
140CPU31110   
Main
range of product
Modicon Quantum automation platform
product or component type
Unity processor
Complementary
clock frequency
66 MHz
number of slots
16
4
10
2
6
number of racks
2 - local rack(s)
number of distributed I/O station
63 station(s) - 1 rack(s) - 3 Modbus Plus network(s)
number of remote I/O station
31 - 2 rack(s) per S908 remote I/O
0 - 0 rack(s) per ethernet remote I/O
discrete I/O number
Unlimited (27 slots max) - local
31744 inputs, 31744 outputs - remote
8000 inputs, 8000 outputs - distributed - per network Modbus Plus
analogue I/O number
Unlimited (27 slots max) - local
500 inputs, 500 outputs - distributed - per network Modbus Plus
1984 inputs,1984 outputs - S908 remote I/O
application specific I/O
High-speed interrupt inputs
Counter
Accurate time stamping
Serial link
number of optional modules
2 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
maximum number of connections
1 USB
2 AS-Interface - distributed
2 Ethernet TCP/IP - local
2 Modbus Plus - local
2 Modbus (RS232/485 Modbus/ASCII)
2 Profibus DP - local
4 AS-Interface - remote
integrated connection type
1 Modbus Plus with
2 Modbus with
checks
Process control
memory description
Internal RAM 548 kB
switch function
Slide switch communication port : ASCII/RTU/Memory
Slide switch memory port/off
application structure
1 cyclic/periodic master task -
1 periodic fast task -
16 timer interrupt tasks -
64 I/O interrupt tasks -
64 interrupt tasks -
No auxiliary task -
execution time per instruction
0.1...0.27 µs floating points
0.1...0.27 µs on fixed-point arithmetic
0.12...0.585 µs Boolean
0.12...0.585 µs on word
number of instructions per ms
1.86 Kinst/ms 100 % Boolean
2.49 Kinst/ms 65 % Boolean and 35 % numerical
system overhead
0.2 ms for fast task
1 ms for master task
bus current requirement
1800 mA
local signalling
1 LED (green)communications are active on the Modbus Plus port (Modbus Plus):
1 LED (green)communications are active on the Modbus port (Modbus):
1 LED (green)CPU has been started and is solving logic (RUN):
1 LED (green)CPU has passed the power-up diagnostic tests (READY):
1 LED (orange)write-protected memory (memory port):
1 LED (red)battery needs replacing or is not present (BAT LOW):
1 LED (red)communications error on the Modbus Plus port (ERROR A):
electrical connection
1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network
2 female connectors, connector type: SUB-D 9 for connecting to the Modbus bus
Environment
product certifications
CSA
CE
UL
standards
HazLoc
Contractual warranty
Warranty